Consultation Hotline:0755-83990550
Ch/En
Localhost:Home > E+H > flow > ultrasonic flowmeter >

Prosonic_93T

technical parameter
Measurement principle: non-contact ultrasonic flow measurement system
Main features: Portable transmitter technology, suitable for volume flow measurement of conventional liquids
Nominal caliber: DN 15... 65 (1/2"... 2 1/2") DN 50... 300 (2"... 12") DN 100... 4000 (4"... 160 ""
Measurement range: 0... 452'389 m3/h
Process temperature: DN 15...65:-40...+150 C (-40...+302 F) DN 50... 300: -40...+170 C (-40...+338 F) DN 100... 4000: -40...+80 C (-40...+176 F)
Pressure range: no pressure limit
Measurement error: +2%
Communication mode: FXA 193
Output signal: current output 4.. 20 mA
Built-in data recording module, data can be exported through USB flash memory
Input signal: current input 4.. 20 mA
Explosion-proof certification:-
Protection Level: Transmitter: IP40
Sensor: IP67/68
Display/Operation: Four-Line LCD Backlight Display Touch Key Operation
Advantages: Data backup management of up to 20 groups of stations for on-line detection of pipeline flow, no need to re-input non-contact measurement mode, with portable transmitter, safe and convenient for use in all kinds of metal and plastic pipes and composite pipes with or without lining, bi-directional measurement, no pressure loss installed outside the pipeline, no need to interrupt the process technology applicable to all kinds of pipelines. Metal and plastic pipes and composite pipes with or without lining