Consultation Hotline:0755-83990550
Ch/En
Localhost:Home > E+H > flow > cmf >

CNGmass

Measurement Principle: Coriolis Force Mass Flow Measurement
Product features: Flowmeters used in fuel-adding applications are easy to integrate. Accurate Measurement of Compressed Natural Gas (CNG) in High Pressure Fuel Addition Applications.
Sensor Characteristics: Excellent Operational Safety: Reliable Measurement in Extreme Environmental Conditions
Less Process Measurement Points: Multivariate Measurements (Flow, Density, Temperature)
Save installation space: Maximum flow rate of 150 kg/min (330 lb/min) and maximum process pressure of 350 bar (5080 psi) are required for the length of straight pipe section without front and rear.
Transmitter features: easy to operate: reduce application requirements
Fast debugging: Preset instrument automatically replies data for service rugged integrated transmitter case Modbus 485
Nominal Caliber Range: DN 8... 25 (niche... 1")
Material for liquid receiving parts: measuring tube: 1.4435 (316L)
Process Connection: 1.4404 (316)
Measurement variables: mass flow, density, temperature, volume flow
Maximum measurement error: mass flow: 0.5% per batch
Volume Flow (Liquid): +0.15% (Reference Conditions)
Measuring range: 0 150 kg / min (0 330 lb / min)
Maximum process pressure: 350 bar (5080 psi)
Medium temperature range: - 50... + 125 degree C (- 58... + 257 degree F)
Ambient temperature range: - 40... + 60 degree C (- 40... + 140 degree F)
Sensor case material: 1.4301 (304L), corrosion resistance
Transmitter Shell Material: Powder Die Cast Aluminum
Protection Level: IP67, Type 4X (Shell)
Display/operation: no field operation through debugging tool settings
Output: Pulse/Frequency/Switch Output (Passive), Phase Shift Pulse
Input: None
Digital communication: Modbus RS485
Power supply voltage: 10.30 V DC, 20.28 V AC
Ex certification: ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI
Other Certificates and Certificates: 3.1 Material Certificate, perform calibration on certified calibration equipment (conforming to ISO/IEC 17025 standard), metering handover, CRN