Localhost:Home > E+H > flow > cmf >

mass_40E

technical parameter
Gas
Measurement Principle: Coriolis Force Mass Flow Measurement System
Main features: Suitable for simple liquid and gas applications, instead of traditional volume flow measurement economical scheme
Nominal caliber: DN 8... 80 (5/16"... 3 ""
Range of measurement: 0. 180000 kg/h
Process temperature: - 40... + 140 degree C (-40 _ + 284 degrees F)
Pressure range: PN 40... 100 CL 150... 300 JIS 10... 20K
Measurement error: mass flow: +1.0%
Communication mode: HART
Output signal: current output 4.. 20 mA Frequency Output State Output
Input signal: state input
Explosion-proof certification: ATEX FM CSA
Protection Level: IP 67 (NEMA 4x)
Display/Operation: Two Lines Backlight Live Display
Advantages: Operation through HART communication or Fieldcare debugging software. Easy installation, economical plant life cycle management W@M without considering the length of straight pipe section before and after installation.
liquid
Measurement Principle: Coriolis Force Mass Flow Measurement System
Main features: Suitable for simple liquid and gas applications
Nominal caliber: DN 8... 80 (5/16"... 3 ""
Range of measurement: 0. 180000 kg/h
Process temperature: - 40... + 140 degree C (-40 _ + 284 degrees F)
Ambient temperature: - 20... + 60 degree C (optional - 40 _ + 60 degrees C)
Pressure range: PN 40... 100 CL 150... 300 JIS 10... 20K
Measurement error: mass flow: +0.5%
Volume flow: +0.5%
Communication mode: HART
Output signal: current output 4.. 20 mA Frequency Output State Output
Input signal: state input
Explosion-proof certification: ATEX FM CSA
Protection Level: IP 67 (NEMA 4x)
Display/Operation: Two Lines Backlight Live Display
Advantages: Operation through HART communication or Fieldcare debugging software. Easy installation, economical plant life cycle management W@M without considering the length of straight pipe section before and after installation.