Consultation Hotline:0755-83990550
Ch/En
Localhost:Home > E+H > flow > cmf >

mass_E_100

technical parameter
Gas
Measurement Principle: Coriolis Force Mass Flow Measurement System
Main features: Ultra-compact flowmeter, multi-variable mass flow measurement system for basic liquid and gas applications, extremely high precision measurement
Nominal caliber: DN 8... 80 (5/16"... 3 ""
Range of measurement: 0. 180000 kg/h
Process temperature: - 40... + 140 degree C (-40 _ + 284 degrees F)
Environmental Temperature Standard: - 40... + 60 degrees C (- 40... + 140 degrees F)
Optional: - 50... + 60 degrees C (- 58... + 140 degrees F)
Maximum process pressure: PN 100 CL 600 63K
Measurement error mass flow: +0.75%
Communication: HART, Modbus RS485, EtherNet/IP, PROFIBUS DP
Output Signal: Current Output 4... 20 mA Pulse/Frequency/State Output (10KHz, Passive)
Input signal:-
Explosion-proof certification: ATEX cCSAus IECEx
Other certifications and certificates: 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, PED, CRN, 3A
Protection level: P 66/67 (NEMA 4x) optional: 69K
Display/Operation: Flowmeter has built-in network server for fast debugging
Advantages: Simultaneously multi-variable parameter measurement: mass flow, volume flow, density and temperature-balance dual-tube measurement system, strong vibration resistance, measurement is completely independent of fluid physical characteristics, simple design, easy debugging, ultra-compact field shell, using cast aluminium or stainless steel, IP69K protection grade and built-in network server can be selected. Easy to debug quickly without special software or tools. Economical Factory Life Cycle Management W@M
liquid
Measurement Principle: Coriolis Force Mass Flow Measurement System
Main features: Ultra-compact flowmeter, multi-variable mass flow measurement system for basic liquid and gas applications, extremely high precision measurement
Nominal caliber: DN 8... 80 (5/16"... 3 ""
Range of measurement: 0. 180000 kg/h (0... 6600 lb/min)
Process temperature: - 40... + 140 degree C (-40 _ + 284 degrees F)
Environmental Temperature Standard: - 40... + 60 degrees C (- 40... + 140 degrees F)
Optional: - 50... + 60 degrees C (- 58... + 140 degrees F)
Maximum process pressure: PN 100 CL 600 63K
Measurement error: mass flow: +0.20% volume flow: +0.20%
Communication mode: EtherNet/IP MODBUS RS485
Output Signal: Current Output 4... 20 mA Pulse/Frequency/State Output (10KHz, Passive)
Input signal:-
Explosion-proof certification: ATEX cCSAus IECEx
Protection Level: IP 66/67 (NEMA 4x)
Optional: IP 69K
Display/Operation: Flowmeter has built-in network server for fast debugging
Advantages: Balanced two-tube measurement system, strong vibration resistance, simultaneous measurement of multi-variable parameters: mass flow, volume flow, density and temperature
· Ultra-compact on-site shell, made of cast aluminium or stainless steel, IP69K protection level is optional
· Built-in network server for fast debugging without special software or tools
· HistoROM automatically stores data to ensure data security
· No need to consider the length of straight pipe before and after installation is simple.
· Economic Plant Life Cycle Management W@M