Prowirl_F_200

Gas
Measurement Principle: Vortex Street Flow Measurement
Product features: Flowmeter adopts economical clamping design, providing integrated or split instruments. Built-in temperature measurement is suitable for mass and energy measurement of saturated steam. Suitable for all basic applications, as well as with 1 pair of 1 replacement orifice plate occasions.
Sensor features: easy alignment sensor: with center ring
High Applicability: Verified Structural Firmness, Vibration Resistance, Temperature Impact-Water Hammer
Maintenance Free: Life Calibration Installation Length 65 mm (2.56 in) Can't Blue
Transmitter Features: Instrument Wiring Convenience: Independent Cavity Operation Safety: Using Backlight Display Unit with Touch Keys without Opening Instrument Built-in Verification: Heartbeat Display Module with Dual Cavity Shell with Strong Data Output Function Structure
Nominal Caliber Range: DN 15... 150 (... 6")
Material of liquid receiving parts: measuring tube: 1.4408 (C3FM) DSC sensor: 1.4435 (316/316L)
Measurement variables: volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
Maximum measurement error: volume flow (liquid): +0.75% volume flow (steam, gas): +1.00% mass flow (liquid): +0.85% mass flow (steam, gas): +1.7%.
Measuring range liquid: 0.16... 625 m_/h (0.09... 368 ft_/min)
Depending on the medium: water, 1 bar a (14.5 psia), 20 degree C (68 degree F) steam and gas: 2 8342 m/h (1.18 4910 ft/min), depending on the medium: steam, 180 degree C (356 degree F), 10 bar a (145 psia) air, 25 degree C (77 degree F), 4.4 bar a (63.8 psia) maximum process pressure PN 40, Cl. 300, 20K medium temperature range standard: - 40... + 260 degree C (- 77 degree F), 4 bar a (63.8 psia). 0... + 500 degrees F)
HIGH/LOW TEMPERATURE (OPTIONS): - 200... + 400 ~C (- 328... + 752 ~F)
High/Low Temperature (Special Selection): - 200... + 450 C (- 328... + 842 F)
Environmental Temperature Range: Integrated Instrument (Standard): - 40...+80 C (- 40...+176 F) Integrated Instrument (Option): - 50...+80 C (- 58...+176 F) Separate Instrument (Standard): - 40...+85 C (- 40...+185 F) Separate Instrument (Option): - 50 85 C (- 58 185 F)
Sensor case material: Sensor connection case: AlSi10Mg coating, 1.4408 (CF3M)
Transmitter case material: AlSi10Mg coating, 1.4404 (316L)
Protection Level: Integral Instrument: IP66/67, Type 4X (Shell) Separate Sensor: IP66/67, Type 4X (Shell) Separate Transmitter: IP66/67, Type 4X (Shell)
Display/Operation: Four-line backlight display, touch key control (external operation) through the field display unit and debugging tools to set up optional separate display
Output: 4... 20 mA HART (Passive) 4... 20 mA (Passive) Pulse/Frequency/Switch Output (Passive)
Input: 4... 20 mA (passive)
Digital Communication: HART, PROFIBUS PA
Supply Voltage: 12.35 V DC (4.20 mA HART, with/without pulse/frequency/switching output) 12.30 V (4.20 mA HART, 4.20 mA) 12.35 V DC (4.20 mA HART, pulse/frequency/switching output, 4... 20 mA input)
Ex certification: ATEX, IECEx, cCSAus
Other Certificates and Certificates: 3.1 Material Certificate, perform calibration on certified calibration equipment (conforming to ISO/IEC 17025 standard), NAMUR, SIL, PED, CRN, NACE MR0175/MR0103, PMI (special selection)
liquid
Measurement Principle: Vortex Street Flow Measurement
Product features: high-precision steam flow measurement flowmeter, with wet steam detection, provide an integrated or split instrument. Built-in temperature measurement is suitable for mass and energy measurement of saturated steam. It is widely used. Optimize steam application.
Sensor features: high process safety: dual sensor type for redundancy measurement
High Applicability: Verified Structural Firmness, Vibration Resistance, Temperature Impact-Water Hammer
No Maintenance: Life Calibration
Wet steam detection: suitable for length compensation of DN 25... 100 (1... 4") front straight pipe section
Transmitter Characteristics: Instrument Wiring Convenience: Independent Wiring Cavity
Operational Safety: Backlight Display Unit with Touch Keys, No Instrument Opening
Built-in Verification: Heartbeat Display Module with Data Output Function Strong Dual-chamber Shell
Nominal caliber range: DN 15... 300 12 ""
Material of liquid-receiving parts: measuring tube: 1.4408 (C3FM); CX2MW, similar to Alloy C22 alloy 2.4602
DSC sensor: 1.4435 (316/316L); UNS N06022, similar to Alloy C22 alloy 2.4602
Process connection: 1.4404 (F316/F316L); CX2MW, similar to Alloy C22 alloy 2.4602; 1.4408 (CF3M)
Measurement variables: volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
Maximum measurement error: volume flow (liquid): +0.75%
Volume flow (steam, gas): +1.00%
Mass flow rate (liquid): +0.85%
Mass flow rate (steam, gas): +1.7%
Measuring range liquid: 0.16... 2412 m/h (0.09... 1420 ft_/min)
Depending on the medium: water, 1 bar a (14.5 psia), 20 degree C (68 degree F), steam, gas: 2... 32 166 m_/h (1.18... 18 932 ft_/min)
Depending on the medium: steam, 180 degree C (356 degree F), 10 bar a (145 psia) air, 25 degree C (77 degree F), 4.4 bar a (63.8 psia)
Maximum process pressure: PN 40, Cl. 300, 20K
Medium Temperature Range Standard: - 40... + 260 C (- 40... + 500 F)
HIGH/LOW TEMPERATURE (OPTIONS): - 200... + 400 ~C (- 328... + 752 ~F)
High/Low Temperature (Special Selection): - 200... + 450 C (- 328... + 842 F)
Environmental Temperature Range: Integrated Instrument (Standard): - 40... + 80 degree C (- 40... + 176 degree F)
Integrated Instrument (Option): - 50... + 80 C (- 58... + 176 F)
Separate Instrument (Standard): - 40... + 85 C (- 40... + 185 F)
Separate Instruments (Options): - 50... + 85 C (- 58... + 185 F)
Sensor Shell Material Sensor Connection Shell: AlSi10Mg Aluminum Alloy Coating, 1.4408 (CF3M) Transmitter Shell Material AlSi10Mg Aluminum Alloy Coating, 1.4404 (316L)
Protection Level: Integrated Instrument: IP66/67, Type 4X (Shell)
Separate Sensors: IP66/67, Type 4X (Shell)
Separate Transmitter: IP66/67, Type 4X (Shell)
Display/Operation: Four-line backlight display, touch key control (external operation) through the field display unit and debugging tools to set up optional separate display
Output: 4... 20 mA HART (Passive) 4... 20 mA (Passive) Pulse/Frequency/Switch Output (Passive)
Input: 4... 20 mA (passive)
Digital Communication: HART, PROFIBUS PA
Supply Voltage: 12.35 V DC (4.20 mA HART, with/without pulse/frequency/switching output) 12.30 V (4.20 mA HART, 4.20 mA) 12.35 V DC (4.20 mA HART, pulse/frequency/switching output, 4... 20 mA input) 9.32 V (PROFIBUS PA, Pulse/Frequency/Switch Output)
Ex certification: ATEX, IECEx, cCSAus
Other Certificates and Certificates: 3.1 Material Certificate, perform calibration on certified calibration equipment (conforming to ISO/IEC 17025 standard), NAMUR, SIL, PED, CRN, AD 2000, NACE MR0175/MR0103, PMI (Special Type Selection) welding test conforming to ISO 15614-1 standard, similar to ASME IX (Special Type Selection)
 
steam
Measurement Principle: Vortex Street Flow Measurement
Product features: high-precision steam flow measurement flowmeter, with wet steam detection, provide an integrated or split instrument. Built-in temperature measurement is suitable for mass and energy measurement of saturated steam. It is widely used. Optimize steam application.
Sensor features: high process safety: dual sensor type for redundancy measurement
High Applicability: Verified Structural Firmness, Vibration Resistance, Temperature Impact-Water Hammer
No Maintenance: Life Calibration
Wet steam detection: suitable for length compensation of DN 25... 100 (1... 4") front straight pipe section
Nominal caliber range: DN 15... 300 12 ""
Measuring range liquid: 0.16... 2412 m/h (0.09... 1420 ft_/min)
Depending on the medium: water, 1 bar a (14.5 psia), 20 degree C (68 degree F), steam, gas: 2... 32 166 m_/h (1.18... 18 932 ft_/min)
Depending on the medium: steam, 180 degree C (356 degree F), 10 bar a (145 psia) air, 25 degree C (77 degree F), 4.4 bar a (63.8 psia)
Medium Temperature Range: Standard: - 40... + 260 degree C (- 40... + 500 degree F)
HIGH/LOW TEMPERATURE (OPTIONS): - 200... + 400 ~C (- 328... + 752 ~F)
High/Low Temperature (Special Selection): - 200... + 450 C (- 328... + 842 F) Maximum Process Pressure PN 40, Cl. 300, 20K
Maximum measurement error: volume flow (liquid): +0.75%
Volume flow (steam, gas): +1.00%
Mass flow rate (liquid): +0.85%
Mass flow rate (steam, gas): +1.7%
Digital Communication: HART, PROFIBUS PA
Output: 4... 20 mA HART (Passive) 4... 20 mA (Passive) Pulse/Frequency/Switch Output (Passive)
Input: 4... 20 mA (passive)
Ex certification: ATEX, IECEx, cCSAus
Protection Level: Integrated Instrument: IP66/67, Type 4X (Shell)
Separate Sensors: IP66/67, Type 4X (Shell)
Separate Transmitter: IP66/67, Type 4X (Shell)
Display/operation: four-line backlight display, touch key control (external operation)
Setting Optional Separate Display by Field Display Unit and Debugging Tool