Consultation Hotline:0755-83990550
Ch/En
Localhost:Home > E+H > flow > Vortex Flowmeter >

Prowirl_O_200

technical parameter
Gas
Measurement Principle: Vortex Street Flow Measurement
Product features: Flowmeter with high-pressure sensor, provide integrated or split instrument.
Built-in temperature measurement, maximum pressure PN 160 (Cl. 600).
Special for high process pressure applications.
Sensor characteristics: high mechanical integration in flow measurement: special measuring tube material
High Applicability: Verified Structural Firmness, Vibration Resistance, Temperature Impact-Water Hammer
No Maintenance: Life Calibration
The maximum pressure is PN 160 (Cl. 600)
DSC sensor is made of titanium (PN > 160 bar / Cl. 600)
Convenient wiring of instrument: independent wiring chamber
Operational Safety: Backlight Display Unit with Touch Keys, No Instrument Opening
Built-in Validation: Heartbeat Technology
Display module with data output function
Strong double chamber housing
Nominal caliber range DN 15... 150. 6 ""
Material of liquid receiving parts: measuring tube: 1.4408 (C3FM); 1.4571, similar to 316Ti
DSC sensor: UNS N07718, similar to Alloy 718 Alloy 2.4668; Titanium grade 5, similar to 3.7165
Process connection: 1.4408 (CF3M); 1.4571, similar to F316 Ti; F316/F316L, similar to 1.4404
Measurement variables: volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
Maximum measurement error: volume flow (liquid): +0.75%
Volume flow (steam, gas): +1.00%
Mass flow rate (liquid): +0.85%
Mass flow rate (steam, gas): +1.7%
Measurement range: liquid: 0.16... 545 m/h (0.09... 321 ft_/min)
Depending on the medium:
Water, 1 bar a (14.5 psia), 20 ~C (68 ~F)
Steam, Gas: 2. 7262 m/h (1.18... 4274 ft_/min)
Depending on the medium:
Steam, 180 degree C (356 degree F), 10 bar a (145 psia)
Air, 25 degrees C (77 degrees F), 4.4 bar a (63.8 psia)
Maximum process pressure PN 250, Cl. 1500, 40K
Medium temperature range PN 63... 160, Cl. 600: - 200... + 400 degree C (- 328... + 752 degree F)
PN 250, Cl. 900... 1 500: - 50... + 400 C (- 58... + 752 F
Environmental Temperature Range: Integrated Instrument (Standard): - 40... + 80 degree C (- 40... + 176 degree F)
Integrated Instrument (Option): - 50... + 80 C (- 58... + 176 F)
Separate Instrument (Standard): - 40... + 85 C (- 40... + 185 F)
Separate Instruments (Options): - 50... + 85 C (- 58... + 185 F)
Sensor Shell Material: AlSi10Mg Aluminum Alloy Coating, 1.4408 (CF3M)
Transmitter case material AlSi10Mg coating, 1.4404 (316L)
Protection Level Integrated Instrument: IP66/67, Type 4X (Shell)
Separate Sensors: IP66/67, Type 4X (Shell)
Separate Transmitter: IP66/67, Type 4X (Shell)
Display/Operate Four-Line Backlight Display with Touch Key Control (External Operations)
Setting up by field display unit and debugging tool
Optional Separated Display
Output 4... 20 mA HART (Passive)
4... 20 mA (passive)
Pulse/Frequency/Switch Output (Passive)
Input 4... 20 mA (passive)
Digital Communication HART, PROFIBUS PA
Power supply voltage 12.35 V DC (4.20 mA HART, with/without pulse/frequency/switching output)
12.30 V (4.20 mA HART, 4.20 mA)
12.35 V DC (4.20 mA HART, Pulse/Frequency/Switch Output, 4... 20 mA input)
9.32 V (PROFIBUS PA, Pulse/Frequency/Switch Output)
Ex Certification ATEX, IECEx, cCSAus
Other Certificates and Certificates 3.1 Material Certificates, perform calibration on certified calibration equipment (conforming to ISO/IEC 17025 standard).
NAMUR, SIL, PED, CRN, AD 2000, NACE MR0175/MR0103, PMI (Special Selection)
Applicable only to Cl. 900/1500: Welding test conforms to ISO 15614-1 standard, similar to ASME IX (Special Selection)
 
liquid
 
Measurement Principle: Vortex Street Flow Measurement
Product features: Flowmeter with high-pressure sensor, provide integrated or split instrument.
Built-in temperature measurement, maximum pressure PN 160 (Cl. 600).
Special for high process pressure applications.
Sensor characteristics: high mechanical integration in flow measurement: special measuring tube material
High Applicability: Verified Structural Firmness, Vibration Resistance, Temperature Impact-Water Hammer
No Maintenance: Life Calibration
The maximum pressure is PN 160 (Cl. 600)
DSC sensor is made of titanium (PN > 160 bar / Cl. 600)
Convenient wiring of instrument: independent wiring chamber
Operational Safety: Backlight Display Unit with Touch Keys, No Instrument Opening
Built-in Validation: Heartbeat Technology
Display module with data output function
Strong double chamber housing
Nominal caliber range DN 15... 150. 6 ""
Material of liquid receiving parts: measuring tube: 1.4408 (C3FM); 1.4571, similar to 316Ti
DSC sensor: UNS N07718, similar to Alloy 718 Alloy 2.4668; Titanium grade 5, similar to 3.7165
Process connection: 1.4408 (CF3M); 1.4571, similar to F316 Ti; F316/F316L, similar to 1.4404
Measurement variables: volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
Maximum measurement error: volume flow (liquid): +0.75%
Volume flow (steam, gas): +1.00%
Mass flow rate (liquid): +0.85%
Mass flow rate (steam, gas): +1.7%
Measurement range: liquid: 0.16... 545 m/h (0.09... 321 ft_/min)
Depending on the medium:
Water, 1 bar a (14.5 psia), 20 ~C (68 ~F)
Steam, Gas: 2. 7262 m/h (1.18... 4274 ft_/min)
Depending on the medium:
Steam, 180 degree C (356 degree F), 10 bar a (145 psia)
Air, 25 degrees C (77 degrees F), 4.4 bar a (63.8 psia)
Maximum process pressure PN 250, Cl. 1500, 40K
Medium temperature range PN 63... 160, Cl. 600: - 200... + 400 degree C (- 328... + 752 degree F)
PN 250, Cl. 900... 1 500: - 50... + 400 C (- 58... + 752 F)
Environmental Temperature Range: Integrated Instrument (Standard): - 40... + 80 degree C (- 40... + 176 degree F)
Integrated Instrument (Option): - 50... + 80 C (- 58... + 176 F)
Separate Instrument (Standard): - 40... + 85 C (- 40... + 185 F)
Separate Instruments (Options): - 50... + 85 C (- 58... + 185 F)
Sensor Shell Material: AlSi10Mg Aluminum Alloy Coating, 1.4408 (CF3M)
Transmitter case material AlSi10Mg coating, 1.4404 (316L)
Protection Level Integrated Instrument: IP66/67, Type 4X (Shell)
 
steam
 
Measurement Principle: Vortex Street Flow Measurement
Product features: Flowmeter with high-pressure sensor, provide integrated or split instrument.
Built-in temperature measurement, maximum pressure PN 160 (Cl. 600).
Special for high process pressure applications.
Sensor characteristics: high mechanical integration in flow measurement: special measuring tube material
High Applicability: Verified Structural Firmness, Vibration Resistance, Temperature Impact-Water Hammer
No Maintenance: Life Calibration
The maximum pressure is PN 160 (Cl. 600)
DSC sensor is made of titanium (PN > 160 bar / Cl. 600)
Nominal caliber range DN 15... 150. 6 ""
Measurement range: liquid: 0.16... 545 m/h (0.09... 321 ft_/min)
Depending on the medium:
Water, 1 bar a (14.5 psia), 20 ~C (68 ~F)
Steam, Gas: 2. 7262 m/h (1.18... 4274 ft_/min)
Depending on the medium:
Steam, 180 degree C (356 degree F), 10 bar a (145 psia)
Air, 25 degrees C (77 degrees F), 4.4 bar a (63.8 psia)
Medium temperature range PN 63... 160, Cl. 600: - 200... + 400 degree C (- 328... + 752 degree F)
PN 250, Cl. 900... 1 500: - 50... + 400 C (- 58... + 752 F)
Maximum process pressure PN 250, Cl. 1500, 40K
Maximum measurement error: volume flow (liquid): +0.75%
Volume flow (steam, gas): +1.00%
Mass flow rate (liquid): +0.85%
Mass flow rate (steam, gas): +1.7%
Digital Communication HART, PROFIBUS PA
Output 4... 20 mA HART (Passive)
4... 20 mA (passive)
Pulse/Frequency/Switch Output (Passive)
Input 4... 20 mA (passive)
Ex Certification ATEX, IECEx, cCSAus
Protection Level Integrated Instrument: IP66/67, Type 4X (Shell)
Separate Sensors: IP66/67, Type 4X (Shell)
Separate Transmitter: IP66/67, Type 4X (Shell)
Display/Operate Four-Line Backlight Display with Touch Key Control (External Operations)
Setting up by field display unit and debugging tool
Optional Separated Display