Prosonic_FMU41

technical parameter
Continuum/liquid
 
Measurement Principle: Ultrasound Level Instrument
Characteristic/Application: Integrated Ultrasound Transmitter
Power/Communication: Two-Wire/Four-Wire System (HART), PROFIBUS PA, Foundation Fieldbus (FF)
Measurement accuracy: +/-2 mm or set range +/-0.2%
Ambient temperature: - 40 degree C... + 80 degree C (- 40 degree F... + 176 degree F)
Process Temperature: - 40 C... + 80 C (- 40 F... + 176 F)
Process Pressure (Absolute Pressure)/Maximum Overpressure Limited Value: 0.7 Bar... 3 Barabs (10 psi... 44 psi), Main Fluid Connection Component PVDF
Process Connection: G/NPT 2“
Blind zone distance: 0.35 m (1.15 ft)
Maximum measuring distance: 8 m (26 ft)
Output: 4... 20 mA HART, PROFIBUS PA, Foundation Fieldbus (FF)
Certificate/certification: ATEX, FM, CSA, TIIS, NEPSI
Application limitations: strong chemical corrosion: FMU42 / FDU9x, foam / strong disturbance: FMU42 / FDU91, fast feeding / discharging: FMU90 + FDU9x, limit detection: FMU90 + FDU9x
technical parameter
Continuum/Solid
Measurement Principle: Ultrasound Level Instrument
Characteristic/Application: Integrated Ultrasound Transmitter
Power/Communication: Two-Wire/Four-Wire System (HART), PROFIBUS PA, Foundation Fieldbus (FF)
Measurement accuracy: +/-2 mm or set range +/-0.2%
Ambient temperature: - 40 degree C... + 80 degree C (- 40 degree F... + 176 degree F)
Process Temperature: - 40 C... + 80 C (- 40 F... + 176 F)
Process Pressure (Absolute Pressure)/Maximum Overpressure Limited Value: 0.7 Bar... 3 Barabs (10 psi... 44 psi), Main Fluid Connection Component PVDF
Process Connection: G/NPT 2“
Blind zone distance: 0.35 m (1.15 ft)
Maximum measuring distance: 3.5 m (11 ft)
Output: 4... 20 mA HART, PROFIBUS PA, Golden Club Fieldbus (FF)
Certificate/Certification: ATEXFMCSATIISNEPSI
Application Limitations: Attention to Measurement Range Graphics
 
 
technical parameter
liquid
Measurement Principle: Ultrasound Level Instrument
Main features: integrated ultrasonic measuring instrument, economic solution of large caliber
Caliber: unlimited (open channel)
Measuring range: unlimited (measuring distance: 0.4... 8 m [1.3... 26 ft])
Process Temperature: - 40 C... + 80 C (- 40 F... + 176 F)
Pressure range: atmospheric pressure
Measurement error: low accuracy
Communication: PROFIBUS PA, Golden Club Fieldbus (FF)
Output: 4... 20 mA (HART), PA, Foundation Fieldbus (FF)
Input: Two-wire system, 16... 36 V DC
Four-wire system, 16.36 V DC
90... 253 V AC, 50/60 Hz
Explosion-proof Certification (Ex): ATEX\FM\CSA
Protection Level: IP68
Advantages: Follow-up installation is possible