Consultation Hotline:0755-83990550
Ch/En
Localhost:Home > E+H > Location > Ultrasonic >

Prosonic_FDU91

Continuum/liquid
Measurement Principle: Ultrasound Level Instrument
Characteristic/Application: Separate instrument with on-site housing or top rail mounting housing for installation in control cabinet, the distance between sensor and transmitter is 300 m
Power/communication: four-wire system (HART, PROFIBUS DP)
Measurement accuracy: +/-2mm + 0.17% of measurement distance
Ambient temperature: - 40 degree C... + 80 degree C (- 40 degree F... + 176 degree F)
Process temperature: - 40 C... + 80 C (- 40 F... + 176 F) Process pressure (absolute pressure) / maximum overpressure limit value 0.7 bar.. 4 bar abs (10 psi... 58 psi)
Main liquid-receiving parts: PVDF (full-welded type: IP68/NEMA 6P)
Process Connection: G/NPT 1“
Blind zone distance: 0.3 m (1 ft)
Maximum measuring distance: 10 m (33 ft)
Output: Transmitter: 4... 20 mA HART PROFIBUS DP
Certificate/Authentication: ATEX FM CSA TIIS IECEx Option 24... 20 mA Output
Application restrictions: possible bubble / strong disturbance: FDU92
Flange mounting bracket: FDU91F
Tank inspection: FMU95
Components: Transmitter: FMU90, FMU95
Continuum/Solid
Measurement Principle: Ultrasound Level Instrument
Characteristic/Application: Separate instrument with on-site housing or top rail mounting housing for installation in control cabinet, the distance between sensor and transmitter is 300 m
Power/communication: four-wire system (HART, PROFIBUS DP)
Measurement accuracy: +/-2mm + 0.17% of measurement distance
Ambient temperature: - 40 degree C... + 80 degree C (- 40 degree F... + 176 degree F)
Process temperature: - 40 C... + 80 C (- 40 F... + 176 F) Process pressure (absolute pressure) / maximum overpressure limit value 0.7 bar.. 4 bar abs (10 psi... 58 psi)
Main liquid-receiving parts: PVDF (full-welded type: IP68/NEMA 6P)
Process Connection: G/NPT 1“
Blind zone distance 0.3 m (1 ft)
Maximum measuring distance: 5 m (16 ft)
Output: Transmitter: 4... 20 mA HART PROFIBUS DP
Certificate/Authentication: ATEX FM CSA TIIS Option 24... 20 mA Output
Component: Transmitter: FMU90
 
 
liquid
Measurement Principle: Ultrasound Level Instrument
Main features: economical solution for open channel flow measurement in water/sewage plant with split instrument, field shell or top guide rail mounted shell
Caliber: unlimited (open channel)
Measurement range: unlimited (maximum measurement distance is 10 m (32 ft))
Process Temperature: - 40 C... + 80 C (- 40 F... + 176 F)
Pressure range: atmospheric pressure
Measurement error: measurement accuracy:
Distance measurement: +/-2mm + 0.17%
Resolution: Distance measurement: 1 mm
Communication: PROFIBUS DP HART
Output: Transmitter: 4... 20 mA HART optional: 2nd 4... 20 mA output
Input: Transmitter
Ex Certification: ATEX FM CSA
Protection Level: IP68
Display/Operation: Transmitter
Advantage: It can be installed in the future.
Sensor self-cleaning effect
Sensor immersion installation (IP68/NEMA 6P)
The distance between sensor and transmitter is 300 m
Component Transmitter: FMU90