technical parameter
Continuum/liquid
Measuring Principle: Guided Wave Radar Level Instrument
Features / applications: Premium equipment, rod probe, cable probe, coaxial probe, built-in data storage unit, factory pre calibration, reliable measurement: wave surface + foam surface, medium replacement.
Interface measurement: clear liquid-liquid interface, simultaneous measurement of interface height and total liquid level
Power/communication: two-wire system (HART, PROFIBUS PA), four-wire system (HART)
Measurement accuracy: rod probe: +/-2 m m (0.08 in), cable probe (<= 15 m (49 ft): +/-2 mm (0.08 in), cable probe (> 15 m (49 ft): +/-10 mm (0.39 in), coaxial probe: +/-5 mm (0.2 in), ambient temperature - 40 C (- 40 F (- 40 176 F))
Process Temperature: - 40 C... + 200 C (- 40 F... + 392 F)
Process Pressure (Absolute Pressure)/Maximum Overpressure Limited Value Vacuum:... 40 bar (580 psi)
Main liquid-receiving parts: rod probe: 316L, Alloy C alloy, ceramic, cable probe: 316, 316L, Alloy C alloy, ceramic, coaxial probe: 316L, Alloy C alloy, ceramic, PFA
Process Connection: Thread: G3/4... G1 1/2, MNPT 3/4... MNPT 1/2, Flange: ASME 1/2 "... 8", DN50... DN 200, JIS 10K
Sensor length: rod probe: 10 m (33 ft), cable probe: 45 m (148 ft), coaxial probe: 6 m (20 ft)
Maximum measuring distance: rod probe: 10 m (33 ft); min. DK > 1.6; cable probe: 25 m... 30 m (82 ft... 98 ft); min. DK > 1.6; 30 m... 45 m (98 ft... 148 ft); min. DK > 1.9; coaxial probe: 6 m (20 ft); min DK > 1.4
Output: 4... 20 mA HART, PROFIBUS PA, Foundation Fieldbus (FF)
Certificate/Authentication: ATEX, FM, CSA, CSA C/US, IECEx, NEPSI, WHG Overflow Protection, SIL, EN10204-3.1
Options: split probe with 3 m (9 ft) cable and airtight protection function
Application limitations: horizontal tank: using coaxial probe, corrosive liquid: FMP52, interface measurement: it is recommended to use coaxial system (coaxial probe, bypass tube, guided wave tube), and emulsion interface: FMP55