technical parameter
Continuum/Solid
Measuring Principle: Guided Wave Radar Level Instrument
Features/Applications: Basic equipment, maximum tensile force 12 kN, cable probe, built-in data storage unit, factory pre-calibration, reliable measurement: dust environment, high + narrow silo, container + internal interference device
Power/communication: two-wire system (HART, PROFIBUS PA), four-wire system (HART)
Measurement accuracy: cable probe: +/-2 mm (0.08in)
Ambient temperature: - 40 degree C... + 80 degree C (- 40 degree F... + 176 degree F)
Process Temperature: - 40 C... + 120 C (- 40 F... + 248 F)
Process Pressure (Absolute Pressure) / Maximum Overpressure Limit: Vacuum (...) 16 bar (232 psi)
Main components: cable probe: 304, 316, 316Ti, 316L, PEEK, PPS, PA
Process Connection: Thread: G 3/4, MNPT 3/4
Sensor Length: Cable Probe: 12 m (40 ft)
Maximum measuring distance: cable probe: 12 m (40 ft); min. DK > 1.4
Output: 4... 20 mA HART, PROFIBUS PA, Foundation Fieldbus (FF)
Certificate/certification: ATEX, FM, CSA, CSA C/US, IECEx, NEPSI, SIL
Options: split probe with 3 m (9 ft) cable