Liquicap_FMI21

technical parameter
Continuum/liquid
Measurement Principle: Capacitive Level Measurement
Features/Applications: Double-rod sensors, factory preset, 0%... 100%, high quality, non-corrosive materials (carbon fibers, stainless steel), suitable for corrosive liquid measurement (mainly acid and alkali liquids)
Power/Communication: 10... 30 V DC
Measurement accuracy: < 1%
Ambient temperature: - 40 degree C... 70 degree C (- 40 degree F... 158 degree F)
Process temperature: - 40 degree C... 100 degrees C (- 40 degrees F (-) 212 degrees F)
Process Pressure (Absolute Pressure) / Maximum Overpressure Limited Value: Vacuum... 10 bar (145 psi)
Main components: sensor rod: 316L/1.4404/PP, optional: carbon fiber, PP coating
Process Connection: G 1_and NPT 1_
Sensor Length: Total Sensor Length: 2.5 m
Maximum measuring distance: 2.5 m (8 ft)
Output: 4... 20 mA
Certificate/Authentication: ATEX, WHG/Overflow Protection
Optional: display unit
Features: Optional sensor truncation clip
Application Limitations: Variable Non-conductive Media, Conductivity < 30 US/cm, High Viscosity Liquids, > 2 000 CST