Consultation Hotline:0755-83990550
Ch/En
Localhost:Home > E+H > Location > Capacitive type >

Liquicap_FMI51

technical parameter
Continuum/liquid
Measurement Principle: Capacitive Level Measurement
Characteristic/Application: Fully insulated rod sensor, suitable for standard and harsh process conditions (temperature, pressure, adhesion)
Interface measurement: liquid interface / emulsion liquid
Power/Communication: 12.36 V DC HARTPFM
Measurement accuracy: repeatability, linearity error of 0.1% conductive liquid < 0.25%.
Ambient temperature: - 50 C... + 70 C (- 58 F... + 158 F)
Process temperature: - 80 C 200 C (- 112 F 392 F)
Process Pressure (Absolute Pressure) / Maximum Overpressure Limit: Vacuum...................................................
Main components: insulating materials: PTFE, PFA
Process connections: G1/2, G 3/4, G 1, G 1/2/NPT 1/2, NPT 3, 4, NPT 1 ", NPT 1/2, flange: DN25... / ANSI 1 "... / JIS...
Hygienic process connection: Tri-Clamp ISO02852 clamp with air-tight protection, milk pipe joint, seals installed safely
Sensor length: total length: 6 m (20 ft), shielding end length: max. 2 m (7 ft)
Maximum measuring distance: 0.1 m... 4.0 m (0.3 ft... 13 ft)
Output: 4... 20 mA HART PFM
Certificate/Certification: ATEXTIISNEPSIWHG, Overflow ProtectionSILEHEDG, 3AGL Classification Certification
Options: Separate enclosure, sensor airtight protection
Characteristics: Shield length, factory calibration, replacement value, fast response
Application limitation: non-conductive medium with limited and varied roof space, conductivity < 100 uS/cm, attention to pressure and temperature changes