Micropilot_FMR20

technical parameter
Measuring Principle: Radar Level Instrument
Features/Applications: Water and sewage industries (e.g. ponds, open channels, rivers, pumping stations, rainwater pools, etc.), simple tanks, public works in all industries
Advantages: Bluetooth debugging, operation and maintenance through SmartBlue App
Power/Communication: Two-wire system (4... 20 mA, Bluetooth Wireless Technology and App
Working frequency: K band (about 26 GHz)
Measurement accuracy: +/-2 mm (0.08")
Process temperature: - 40... + 80 degree C (- 40 _ + 176 degrees F)
Process absolute pressure/maximum overpressure limit: -1... 3 bar (-14.50... 43 psi)
Material of liquid-receiving parts: PVDF, PBT
Process connection: thread: G1 ", NPT1"; G1 1/2 ", NPT1 1/2"; G2 ", NPT2", flange: UNI DN80.. DN150 (3 "... 6 ""
Maximum measurement range: 10 m (DN40); 20 m (= > DN80)
Communication: 4... 20mA HART, Bluetooth wireless technology
Certificate/Certification: ATEX, CSA C/US, IEC Ex
Options: Bluetooth remote operation through SmartBlue App, optional simultaneous ordering of separate HART indicator RIA15, anti-immersion hood, multiple installation modes