technical parameter
Limit/liquid
Measurement Principle: Tuning Fork Level Measurement
Features/Applications: Integrated Limit Switch for Low Limit (MIN) and High Limit (MAX) Safety Applications with the highest safety up to SIL3, Double Seal/Second Layer Protection, Modular Shell
Power/Communication: Two-wire system, 4... 20 mA
Ambient temperature: - 60 C... + 70 C (- 76 F... + 160 F)
Process temperature: - 60 C... + 280 C (- 76 F... + 540 F)
Process Pressure (Absolute Pressure) / Maximum Overpressure Limit: Vacuum...................................................
Minimum medium density: 0.4 g/cm3 (0.4 SGU)
Main liquid-receiving parts: 316L, Alloy C alloy
Process Connection: Flange: DN 25... 100, ASME 1 "... 4", JIS 10K... 20K, Thread: G3/4, G1, R3/4, R1, MNPT3/4, MNPT1, Sensor Length Integration
Output: Two-wire system, 4... 20 mA
Certificate/Certification: ATEX, FM, IECEx, Overflow Protection WHG, EN10204-3.1 Material Certificate, NACE
Options: PWIS-free, pressure airtight protection, protective shield
Features: Highlighting Advantages: - Continuous LIVE Signal Monitoring Function Safety, - Failure Safety Design, - High Reliability of Measured Value, Component Nivotester FTL825, Transmitter