Consultation Hotline:0755-83990550
Ch/En
Localhost:Home > E+H > Location > tuning fork >

Liquiphant_M_FTL50H

technical parameter
density
Measurement Principle: Tuning Fork Level Measurement
Features/Applications: Liquiphant M Density Measurement, FML621 with Density Computer, Temperature and Pressure Measurement, Modularization, Full Welded Shell, Focusing on Food and Pharmaceutical Industry, Surface Smoothness up to 0.3u, Compensation Function (optional)
Power/Communication: Transmitter Power Supply (MUS)
Environmental temperature: - 50 C... + 70 C,'- 50 60 C, suitable for dangerous areas
Process temperature: 0 80 C (effective precision parameter), - 50 0 C / 80 150 C (reduced precision parameter)
Process Pressure (Absolute Pressure): 0... 25 bar, > 25... 64 bar (Reduced Precision Parameters)
Contact parts: 316L
Sanitary certification: 3A, EHEDG
Sensor Length: Integrated: 50.5 mm
Output: Pulse
Certificate/Certification: ATEX, IECEx
Features: Debugging with ReadWin2000
Components: Density Computer FML621

technical parameter
Limit/liquid
Measurement Principle: Tuning Fork Level Measurement
Features/Applications: Modular, fully welded shell, focusing on food, pharmaceutical industry, surface finish up to 0.38 um, electropolishing, multi-process connection, analog interface and bus interface, multiple certificates (e.g. EHEDG, 3A), one-in-one, e.g. pipes
Power supply/communication: PROFIBUS PA, 19... 253 V AC, 10... 55 V DC-PNP, 19... 253 V AC, or 10... 55 V DC, 8/16 mA, 11... 36 V DC, NAMUR, PFM
Ambient temperature: - 50 C... + 70 C (- 58 F... + 158 F)
Process temperature: - 50 C... + 150 C (- 58 F... + 302 F)
Process Pressure (Absolute Pressure) / Maximum Overpressure Limit: Vacuum (...) 64 bar (928 psi)
Minimum medium density: 0.5 g/cm 3 (0.4 g/cm 3, optional)
Main liquid-receiving parts: 316L
Process Connection: Thread: G3/4A, G1A, R3/4 ", R1, NPT3/4, NPT1, Flange: DN25... DN100, ASME 1"... 4 ", JIS25A... 100A
Sanitary process connection: Tri-Clamp ISO2852 clamp, milk pipe joint, anti-corrosion joint, DRD, SMS, Varivent
Output: PROFIBUS PA, 19... 253 V AC, 10... 55 V DC-PNP, 19... 253 V AC, or 10... 55 V DC, 8/16 mA, 11... 36 V DC, NAMUR, PFM
Certificate/certification: ATEX, FM, CSA, TIIS, spillover protection WHG, SIL, EN10204-3.1, GL/ABS classification certification, EHEDG, 3A, FDA, USP class VI, ASME-BPE, AD2000
Characteristics: foam detection and density change detection
Components: FTL325P/FTL375P interface PFM, FTL325N/FTL375N interface NAMUR