Consultation Hotline:0755-83990550
Ch/En
Localhost:Home > E+H > Location > tuning fork >

Liquiphant_M_FTL51

technical parameter
density
Measurement Principle: Tuning Fork Level Measurement
Features/Applications: Liquiphant M Density Measurement, FML621 with Density Computer, Temperature and Pressure Measurement, Modular Shell, Multi-process Connection, Extended Pipeline Length up to 3 m (6 m, optional), Used for Compensation (optional)
Power/Communication: Transmitter Power Supply (MUS)
Ambient temperature: - 50 70 C, - 50 60 C, suitable for dangerous areas
The process temperature is 0 80 C (effective precision parameter), - 50 0 C / 80 150 C (reduced precision parameter)
Process Pressure (Absolute Pressure): 0... 25 bar, > 25... 100 bar (Accuracy parameter reduced a)
Contact parts: 316L/C4
Sensor length: 115... 3000 mm, > 3000... 6000 mm (optional)
Output: Pulse
Certificate/Certification: ATEX, IECEx
Features: Debugging with ReadWin2000
Components: Density Computer FML621
technical parameter
Limit/liquid
Measurement Principle: Tuning Fork Level Measurement
Features/Applications: Modular housing, multiple process connections, analog and bus interfaces, multiple certificates (e.g. Ex, WHG), extended pipe length up to 3 m (6 m, optional), for compensation (optional)
Power supply/communication: PROFIBUS PA, 19... 253 V AC, 10... 55 V DC-PNP, 19... 253 V AC, or 10... 55 V DC, 8/16 mA, 11... 36 V DC, NAMUR, PFM
Ambient temperature: - 50 C... + 70 C (- 58 F... + 158 F)
Process temperature: - 50 C... + 150 C (- 58 F... + 302 F)
Process Pressure (Absolute Pressure) / Maximum Overpressure Limit: Vacuum (...) 100 bar
Minimum medium density: 0.5 g/cm 3 (0.4 g/cm 3, optional)
Main liquid-receiving parts: 316L/Alloy alloy
Process Connection: Thread: G3/4A, G1A, R3/4 ", R1, NPT3/4, NPT1, Flange: DN25... DN100, ASME 1"... 4 ", JIS 25A... 100A
Sanitary process connection: Tri-Clamp ISO2852 clamp
Sensor Length: 130 mm (5.12") Liquiphant II, 148 mm... 6000 mm (5.83"... 236")
Output: PROFIBUS PA, 19... 253 V AC, 10... 55 V DC-PNP, 19... 253 V AC, or 10... 55 V DC, 8/16 mA, 11... 36 V DC, NAMUR, PFM
Certificate/Authentication: ATEX, FM, CSA, TIIS, WHG Overflow Protection, SIL, EN10204-3.1, NACE, ASME B31.3
Options: Heavy stainless steel case, mainly for oil and gas industry
Characteristics: foam detection, density change detection, two layer protection
Components: FTL325P/FTL375P interface PFM, FTL325N/FTL375N interface NAMUR