Consultation Hotline:0755-83990550
Ch/En
Localhost:Home > E+H > Location > tuning fork >

Liquiphant_M_FTL51C

technical parameter
density
Measurement Principle: Tuning Fork Level Measurement
Features/Applications: Liquiphant M Density Measurement, FML621 with Density Computer, Temperature and Pressure Measurement, Anticorrosive Coating, Strong Anticorrosive Medium. Modular shell, multi-process connection, extension tube length can reach: 3 m (6 m, optional), for compensation (optional)
Power/Communication: Transmitter Power Supply (MUS)
Ambient temperature: - 50 80 C, - 50 60 C, suitable for dangerous areas
Process temperature: 0 80 C (effective precision parameter), - 50 0 C / 80 150 C (reduced precision parameter)
Process Pressure (Absolute Pressure): 0.25 bar, > 25.40 bar (Reduced Precision Parameters)
Contact parts: ECTFE, PFA and enamel
Sensor length: 115... 3000mm (depending on whether it is covered)
Output: Pulse
Certificate/Certification: ATEX, IECEx
Optional: Debugging with ReadWin2000
Components: Density Computer FML621
technical parameter
Limit/liquid
Measurement Principle: Tuning Fork Level Measurement
Features/Applications: With anticorrosive coating, strong anti-corrosive medium, modular shell, multi-process connection, analog interface and bus interface, multiple certificates (e.g. Ex, WHG), extended pipeline up to 3 m (6 m, optional)
Power/Communication: PROFIBUS PA, 19 253 V AC, two-wire system, 10 55 V DC-PNP, three-wire system, DPDT, 19 253 V AC, 10 55 V DC, 8/16 mA, 11 36 V DC, NAMUR, PFM, two-wire system, NAMUR, with test keys
Ambient temperature: - 50 C... + 70 C (- 58 F... + 158 F)
Process temperature: - 50 C... + 150 C (- 58 F... + 302 F), 230 C (450 F) are optional.
Process Pressure (Absolute Pressure) / Maximum Overpressure Limit: Vacuum (...) 40 bar (580 psi)
Minimum medium density: 0.5 g/cm_ (0.4 g/cm_, optional)
Major liquid-receiving components: ECTFE, PFA (Edlon), PFA (Ruby, PFA (Conductivity), Porcelain Glaze
Process Connection: Flange: DN25... DN100, ASME 1 "... 3", JIS RF10 K 50
Hygienic process connectivity: FDA, through PFA certification (Edlon)
Sensor Length: ECTFE, PFA 130 mm, 148 mm... 3000 mm (ECTFE, PFA 5.12 ", 5.83"... 118"), Porcelain Glaze: 130 mm, 148 mm... 1200 mm (Porcelain Glaze: 5.12", 5.83"... 47.24")?
Output: PROFIBUS PA, 19... 253 V AC, 10... 55 V DC-PNP, 19... 253 V AC, or 10... 55 V DC, 8/16 mA, 11... 36 V DC, NAMUR, PFM
Certificate/Certification: ATEX, FM, CSA, TIIS, WHG Overflow Protection, SIL, EN10204-3.1, GL/ABS Classification Certification, FDA Certification Materials
Options: Heavy Stainless Steel Shell for Oil and Gas Industry
Characteristics: foam detection, density change detection, two protection
Component: FTL325P/FTL375P Interface PFM
FTL325N/FTL375N Interface NAMUR