Soliphant_M_FTM51

technical parameter
Limit/Solid
Measurement Principle: Tuning Fork Level Measurement
Features/Applications: Fine Grain and Powder Limitation Detection, Fork Sensor, Universal, Non-calibration, Not Affected by Adhesion and External Vibration, Structural Firmness
Switch: External Visibility and Extension Tube
Power/Communication: DC PNP, three-wire system, AC, two-wire system, 19... 253 V AC/19 V... 55 V DC, two relay contacts, 8/16 mA, NAMUR, PFM
Ambient temperature: - 50 C... 70 C (- 60 F... 160 F)
Process temperature: - 50 C... 280 C (- 60 F... 540 F)
Process Pressure (Absolute Pressure) / Maximum Overpressure Limit: Vacuum...................................................
Minimum medium density: 10 g/l (8 g/l, optional)
Main components: 316L 3.2 um, 316L 0.8 um, 316L PTFE coating (to avoid adhesion), 316L ETFE coating (to avoid corrosion)
Process Connection: Thread R 1 1/2 ", 1 1/4" NPT, 1 1/2 "NPT, EN flange DN50... DN100, ANSI flange 2"... 4 ", JIS flange 50A... 100A
Sanitary process connection: Tri-Clamp ISO2852 clamp
Sensor length: 300... 4000 mm (12... 155"), (6000 mm / 230), optional)
Output: DC PNP, two-wire system, AC transistor, DPDT relay, 8/16 mA, NAMUR, PFM
Certificate/certification: ATEX, FM, CSA, TIIS, SIL
Options: Glass cap, insulator, EN10204-3.1
Characteristics: Adhesion and corrosion detection, split type, optional three temperatures, SIL 2
Application limitation: grain size, > 10mm (0.4")