Consultation Hotline:0755-83990550
Ch/En
Localhost:Home > E+H > Location > tuning fork >

Soliphant_M_FTM52

technical parameter
Limit/Solid
Measurement Principle: Tuning Fork Level Measurement
Features/Applications: Fine grain and powder location detection, fork sensor, universal, non-calibration, not affected by adhesion and external vibration, strong structure, external visibility of switch point, extension tube
Power/Communication: 10-55V DC PNP, three-wire system, 19-253V AC, two-wire system, 19...253V AC/19V... 55 V DC, two relay contacts, 8/16mA, NAMUR, PFM
Ambient temperature: - 50 C... 70 C (- 60 F... 160 F)
Process temperature: - 40 C 80 C (- 40 F) 170 degrees F)
Process Pressure (Absolute Pressure)/Maximum Overvoltage Limited Value: Vacuum... 2 bar (30 psi), max. 6 bar (80 psi), EExd/EExde
Minimum medium density: 10 g/l (8 g/l, optional)
Main liquid-receiving parts: sensor selection: 316L 3.2um, 316L 0.8um, 316L PTFE coating (avoid adhesion), cable type: PUR, silicon
Maximum Tensile Strength: 3000 N
Process Connection: Thread R 1 1/2 ", 1 1/4" NPT, 1 1/2 "NPT, EN flange DN50... DN100, ANSI flange 2"... 4 ", JIS flange 50A... 100A
Sanitary process connection: Tri-Clamp ISO2852 clamp
Sensor Length: 750... 20000 mm (30... 800")
Output: DC PNP, two-wire system, AC transistor, DPDT relay, 8/16 mA, NAMUR, PFM
Certificate/certification: ATEX, FM, CSA, TISS, SIL
Options: Glass cap, insulator, EN10204-3.1
Characteristics: Adhesion and corrosion detection, split type, optional three temperatures, SIL 2
Application limitation: grain size, > 10mm (0.4")
Components: PFM: FTL325P, FTL375P, NAMUR: FTL325N, FTL375N