Deltabar_M_PMD55

technical parameter
Continuum/liquid
Measurement Principle: Differential Pressure
Features/Applications: Digital Transmitter with Metal Measuring Diaphragm, Compact Size, Modular Transmitter, Long-term Stability
Power/Communication: 4.20 mA HART: 11.5... 45 V DC; Ex ia: 11.5... 30 V DC
Measurement accuracy: 0.1%, platinum type: 0.075%
Long-term stability: 0.05% for range upper limit (URL) and 0.125% for range upper limit (URL) for 5 years
Ambient temperature: - 40 C... 85 C (- 40 F... 185 F)
Process temperature: - 40 degree C... 120 C (- 40 F.) 248 degrees F), process pressure (absolute pressure)/
Maximum Overvoltage Limit: - 40 degree C... 120 C (- 40 F.) 248 degrees F)
Process pressure range: 10 mbar... 40 bar (0.15 psi... 580 psi)
Main liquid-receiving parts: 316L
Process Connection: 1/4-18 NPT
Output: 4... 20 mA HART, PROFIBUS PA, Foundation Fieldbus (FF)
Certificate/certification: ATEX, FM, CSA, IECEx, TIIS, NACE, SIL, EN10204-3.1
Options: Four-line digital display, aluminum case
Application Limitations: Measurement Unit: Metal Welding
technical parameter
Gas
Measurement Principle: Differential Pressure
Main features: digital transmitter, metal measuring diaphragm, compact size, modular transmitter, long-term stability
Process temperature: gradient change along the tapping tube temperature
Pressure range: 10 mbar... 40 bar (0.15 psi... 580 psi)
Measurement error: 0.1%, platinum type: 0.075%.
Communication: HART
Output: 4... 20 mA HART
Explosion-proof Certification (Ex): ATEX, FM, CSA, IECEx
Display/Action: Options
 
 
technical parameter
liquid
Measurement Principle: Differential Pressure
Main features: digital transmitter, metal measuring diaphragm, compact size, modular transmitter, long-term stability
Process temperature: gradient change along the tapping tube temperature
Pressure range: 10 mbar... 40 bar (0.15 psi... 580 psi)
Measurement error: 0.1%, platinum type: 0.075%.
Communication: HART
Output: 4... 20 mA HART
Explosion-proof Certification (Ex): ATEX, FM, CSA, IECEx
Display/Action: Options
 
 
 
technical parameter
pressure
Measurement Principle: Differential Pressure
Features: Digital transmitter with metal measuring diaphragm, compact size, modular transmitter, long-term stability
Power/Communication: 4.20 mA HART: 11.5... 45 V DC; Ex ia: 11.5... 30 V DC, PROFIBUS PA, Foundation Fieldbus (FF)
Measurement accuracy: 0.1%, platinum type: 0.075%
Long-term stability: 0.05% for range upper limit (URL) and 0.125% for range upper limit (URL) for 5 years
Process temperature: - 40 degree C... 120 C (- 40 F.) 248 degrees F)
Ambient temperature: - 40 C... 85 C (- 40 F... 185 F)
Range of measurement: 10 mbar... 40 bar (0.15 psi... 580 psi)
Maximum Overvoltage Limit: One Side: 160 Bar (2300 psi)
Process Connection: 1/4-18 NPT
Output: 4... 20 mA HART
Certificate/certification: ATEX, FM, CSA, IECEx, TIIS, NACE, SIL, EN10204-3.1
Options: Four-line digital display, aluminum case
 
 
technical parameter
steam
Measurement Principle: Differential Pressure
Main features: digital transmitter, metal measuring diaphragm, compact size, modular transmitter, long-term stability
Process temperature: gradient change along the tapping tube temperature
Pressure range: 10 mbar... 40 bar (0.15 psi... 580 psi)
Measurement error: 0.1%, platinum type: 0.075%.
Communication: HART
Output: 4... 20 mA HART
Explosion-proof Certification (Ex): ATEX, FM, CSA, IECEx
Display/Action: Options