Consultation Hotline:0755-83990550
Ch/En
Localhost:Home > E+H > pressure > Differential pressure transmit >

Deltabar_FMD71

Continuum/liquid
Measurement Principle: Differential Pressure Measurement
Characteristics/Applications: Electronic differential pressure transmitter with ceraphire for liquid level, volume or mass measurement.
Power/Communication: 4... 20 mA HART: 12... 45 V DC
Ex ia: 12... 30 V DC
Measurement accuracy: 0.075% for each sensor
"Platinum type": 0.05% long-term stability of each sensor, 0.05% maximum range (URL) of each sensor per year
Ambient temperature: - 40... 80 degree C (- 40 _ 176 degrees F)
Process temperature: - 25... 150 degree C (-13 _ 302 degrees F)
Process adiabatic/maximum overload limit: 60 bar (900 psi)
Pressure measurement range: 100 mbar... 40 bar (1.5... 600 psi)
Process connection: threaded flange (DIN, ANSI, JIS)
Hygienic process connectivity: DIN11851 DIN11864-1 Tri-Clamp DRD Varivent
Output: 4... 20 mA HART
Certificate/certification: ATEX, FM, CSA, IECEx NACE MRO 175 EN10204-3.1 EHEDG 3A optional four-line digital display of stainless steel or aluminum case
Application Limitations: Using Electronic Differential Pressure Selection Software
technical parameter
pressure
Measurement Principle: Differential Pressure Measurement
Characteristics/Applications: Electronic differential pressure transmitter with ceraphire for liquid level, volume or mass measurement.
Power/Communication: 4... 20 mA HART: 12... 45 V DC
Ex ia: 12... 30 V DC
Measurement accuracy: 0.075% for each sensor
"Platinum type": 0.05% long-term stability of each sensor, 0.05% maximum range (URL) of each sensor per year
Process temperature: - 25... 150 degree C (-13 _ 302 degrees F)
Ambient temperature: - 40... 80 degree C (- 40 _ 176 degrees F)
Range of measurement: 100 mbar... 40 bar (1.5... 600 psi)
Maximum overload limit: 60 bar (900 psi)
Process connection: threaded flange (DIN, ANSI, JIS)
Hygienic process connection: DIN11851 DIN11864-1 Tri-Clamp clamp DRD Varivent
Output: 4... 20 mA HART
Certificate/certification: ATEX, FM, CSA, IECEx NACE MRO 175 EN10204-3.1 EHEDG 3A optional four-line digital display of stainless steel or aluminum case
Application Limitations: Using Electronic Differential Pressure Selection Software