Consultation Hotline:0755-83990550
Ch/En
Localhost:Home > E+H > pressure > Process pressure >

Cerabar_M_PMP55

technical parameter
Continuum/liquid
Measurement Principle: Static Pressure
Features/Applications: Intelligent and reliable pressure transmitter, piezoresistive sensor, process isolation diaphragm with metal welding and isolation and sealing system
Power/Communication: 4.20 mA HART: 11.5... 45 V DC; Ex ia: 11.5... 30 V DC, PROFIBUS PA, Foundation Fieldbus (FF)
Measurement accuracy: 0.15%, platinum type: 0.075%
Long-term stability: 0.1% of the upper limit of range (URL) per year
Ambient temperature: - 40 C... 85 C (- 40 F... 185 F)
Process temperature: - 70 degree C.. 400 degrees C (- 94 degrees F (-) 752 degree F), process pressure (absolute pressure)/
Maximum overvoltage limit: 600 bar (9000 psi)
Process pressure range: 1 bar... 400 bar (15 psi... 6000 psi)
Main components: 316L, Alloy C alloy, Monel, Tantalum, Rhodium
Process connection: diaphragm sealing system, flange (DIN, ANSI, JIS), Tri-Clamp ISO2852 clamp, sanitary connection
Maximum measuring distance: 4000m (13.123 ft) H_2O
Output: 4... 20 mA HART, PROFIBUS PA, Foundation Fieldbus (FF)
Certificate/Certification: ATEX, CSA, FM, IECEx, TIIS, NACE, SIL, 3A/EHEDG Certification, Testing Certificate
Options: On-site display
Application limitation: Measuring unit: When metal is welded and under pressure, differential pressure can be measured by two pressure transmitters (electronic differential pressure measurement). Pay attention to the pressure ratio: static pressure.
technical parameter
pressure
Measurement Principle: Static Pressure
Features/Applications: Intelligent and reliable pressure transmitter, piezoresistive sensor, process isolation diaphragm with metal welding and isolation and sealing system
Power/Communication: 4.20 mA HART: 11.5... 45 V DC; Ex ia: 11.5 30 V DC, PROFIBUS PA / Foundation Fieldbus (FF), 9 32 V DC (Non Ex)
Measurement accuracy: 0.15%, platinum type: 0.075%
Long-term stability: 0.1% per year of range upper limit (URL)
Process temperature: - 70 degree C.. 400 degrees C (- 94 degrees F (-) 752 degrees F)
Ambient temperature: - 40 degree C. 85 degrees C (- 40 degrees F (-) 185 degrees F)
Measuring range: 400m bar.... 400 bar. (15 psi.) 6000 psi)
Maximum overvoltage limit: 600 bar (9000 psi)
Process Connection: Thread: G1/2... G2, MNPT1/2... MNPT2, Flange: DN25... DN100, ASME 1 "... 4", JIS 10k, Diaphragm seal, Sanitary Connection: Tri-Clamp, DIN11851, DIN11864-1, UMO, Varivent N, SMS, DRD
Output: 4... 20 mA HART, PROFIBUS PA, Foundation Fieldbus (FF)
Certificate/Certification: ATEX, CSA, FM, IECEx, TIIS, NACE, SIL, 3A/EHEDG Certification, Testing Certificate
Options: On-site display