Consultation Hotline:0755-83990550
Ch/En
Localhost:Home > E+H > pressure > Process pressure >

Cerabar_S_PMP71

technical parameter
Continuum/liquid
Measurement Principle: Static Pressure
Features/Applications: Digital Transmitter, Piezoresistive Transducer, Modular Transmitter with Metal Welding Measuring Diaphragm, High Long-term Stability, Self-diagnostic Function, Effective Safety Improvement, Additional Process Isolation Function
Power/Communication: 4.20 mA HART: 10.5... 45 V DC; Ex ia: 10.5... 30 V DC, PROFIBUS PA / Foundation Fieldbus (FF): 9... 32 V DC
Measurement accuracy: 0.075%, platinum type: 0.05%.
Long-term stability: 0.05% of maximum range (URL) per year
Ambient temperature: - 40 C... 85 C (- 40 F... 185 F)
Process temperature: - 40 C... 125 C (- 40 F 257 degrees F), process pressure (absolute pressure)/
Maximum overvoltage limit: 1050 bar (15,750 psi)
Process pressure range: 100 mbar... 700 bar (1.5 psi... 10,500 psi)
Main components: Alloy C alloy, 316L, rhodium
Process connection: threads, flanges (DIN, ANSI,...), diaphragms with full safety installation
Maximum measuring distance: 7000 m (22,966 ft) H_2O
Output: 4... 20 mA HART, PROFIBUS PA, Foundation Fieldbus (FF)
Certificate/Certification: ATEX, FM, CSA, NEPSI, TIIS, IECEx, SIL, NACE, GL Classification Certification, WHG/Overflow Protection, EN10204-3.1
Options: HistoROM/M-Dat, four-line digital display, stainless steel or aluminium case, separate case
Features: Diagnostic function, multiple operating languages
Application limitation: Measuring unit: When metal is welded and under pressure, differential pressure can be measured by two pressure transmitters (electronic differential pressure measurement). Pay attention to the pressure ratio: static pressure.

technical parameter
pressure
Measurement Principle: Static Pressure
Features: Digital transmitter, piezoresistive sensor, metal welding diaphragm, modular transmitter, high long-term stability, self-diagnostic function, effectively improve safety, with additional process isolation function
Power/Communication: 4.20 mA HART: 10.5... 45 V DC; Ex ia: 10.5... 30 V DC, PROFIBUS PA / Foundation Fieldbus (FF): 9... 32 V DC
Measurement accuracy: 0.075%, platinum type: 0.05%.
Long-term stability: 0.05% of maximum range (URL) per year
Process temperature: - 40 degree C... 125 C (- 40 F.) 257 degrees F)
Ambient temperature: - 40 C... 85 C (- 40 F... 185 F)
Measuring range: 100 mbar... 700 bar (1.5 psi... 10,150 psi)
Maximum over-voltage limit: 1050 bar (15,750 psi), process connection, thread: G1/2... G2, R1/2, MNPT1/2... MNPT2, R1/2, flange: DN25... DN80, ASME 1"... 4", JIS 10K... 20K
Output: 4... 20 mA HART, PROFIBUS PA, Foundation Fieldbus (FF)
Certificate/Certification: ATEX, FM, CSA, TIIS, NEPSI, IECEx, SIL, NACE, GL Classification Certification, WHG/Overflow Protection, EN10204-3.1
Options: HistoROM/M-Dat, four-line digital display, stainless steel or aluminium case, separate case
Characteristics: Diagnostic function