Consultation Hotline:0755-83990550
Ch/En
Localhost:Home > E+H > pressure > Process pressure >

Cerabar_S_PMP75

technical parameter
Continuum/liquid
Measurement Principle: Static Pressure
Features/Applications: Digital Transmitter, Piezoresistive Sensor, Diaphragm Sealing System, Modular Transmitter, High Long-term Stability, Minimum Oil Filling Volume, Self-Diagnosis Function, Effective Improvement of Safety, Additional Process Isolation Function
Power/Communication: 4.20 mA HART: 10.5... 45 V DC; Ex ia: 10.5... 30 V DC, PROFIBUS PA / Foundation Fieldbus (FF): 9... 32 V DC
Measurement accuracy: 0.075%+influence of diaphragm seal system
Long-term stability: 0.05% of maximum range (URL) per year
Ambient temperature: - 40 C... 85 C (- 40 F... 185 F)
Process temperature: - 70 degree C.. 400 degrees C (- 94 degrees F (-) 752 degree F), process pressure (absolute pressure)/
Maximum overvoltage limit: 1050 bar (15,200 psi)
Process pressure range: 100 mbar... 400 bar (1.5 psi... 5800 psi)
Main components: Alloy C alloy, 316L, Monel, Tantalum, PTFE film
Process connection: thread, flange (DIN, ANSI,...), diaphragm with safety installation, Tri-Clamp ISO2852 clamp, sanitary connection, maximum measuring distance 7000 m (22,966 ft) H2O
Output: 4... 20 mA HART, PROFIBUS PA, Foundation Fieldbus (FF)
Certificate/Certification: ATEX, FM, CSA, IECEx, TIIS, NEPSI, SIL, NACE, WHG/Overflow Protection, EN10204-3.1, GL Classification Certification
Options: HistoROM/M-Dat, four-line digital display, stainless steel or aluminium case, separate case
Features: Diagnostic function, multiple operating languages
Application limitation: Measuring unit: When metal is welded and under pressure, differential pressure can be measured by two pressure transmitters (electronic differential pressure measurement). Pay attention to the pressure ratio: static pressure.

technical parameter
pressure
Measurement Principle: Static Pressure
Features: Digital transmitter, piezoresistive sensor, diaphragm sealed system, modular transmitter, high long-term stability, minimum oil filling volume process connection, self-diagnostic function, effectively improving safety, with additional process isolation function
Power/Communication: 4.20 mA HART: 10.5... 45 V DC; Ex ia: 10.5... 30 V DC, PROFIBUS PA / Foundation Fieldbus (FF): 9... 32 V DC
Measurement accuracy: 0.075%+influence of diaphragm seal system
Long-term stability: 0.05% of maximum range (URL) per year
Process temperature: - 70 degree C.. 400 degrees C (- 94 degrees F (-) 752 degrees F)
Ambient temperature: - 40 C... 85 C (- 40 F... 185 F)
Measuring range: 100 mbar... 700 bar (1.5 psi... 10,150 psi)
Maximum overvoltage limit: 1050 bar (15,750 psi)
Process Connection: Thread: G1/2... G2, R1/2, MNPT1/2... MNPT2, NPT1/2... NPT1, Flange: DN25... DN100, ASME 1 "... 4", JIS 10K, Sanitary Connection: Tri-Clamp, DIN11851, Varivent N, SMS, DRD
Output: 4... 20 mA HART, PROFIBUS PA, Foundation Fieldbus (FF)
Certificate/Certification: ATEX, FM, CSA, TIIS, NEPSI, IECEx, SIL, NACE, WHG/Overflow Protection, EN10204-3.1, GL Classification Certification
Options: HistoROM/M-Dat, four-line digital display, stainless steel or aluminium case, separate case
Characteristics: Diagnostic function