technical parameter
Continuum/liquid
Measurement Principle: Static Pressure
Characteristic/Application: Pressure transmitter, used for hydrostatic level measurement, CONTITTE sensor installed safely, with metal measuring diaphragm: -, sealed welding, - absolutely sealed anti-condensation, - anti-climate change, - long-term stability, - minimum temperature effect, rod instrument, used in all process fields, process measurement technology, system Measurement of Liquid and Paste Medium in Pharmaceutical and Food Industry
Power/Communication: 4 20 mA HART: 11.5 45 V DC; Ex ia: 11.5 30 V DC, PROFIBUS PA / Foundation Fieldbus (FF), 9 32 V DC (Non Ex)
Measurement accuracy: 0.2%, optional: 0.1%
Long-term stability: 0.05% of maximum range (URL) per year
Ambient temperature: - 40 degree C. 85 C (- 40 F 185 F)
Process temperature: - 10 degree C... 85 degrees C (14 degrees F... 212 degree F), process pressure (absolute pressure)/
Maximum overvoltage limit: 40 bar (600 psi)
Pressure measurement range: 100 mbar... 10 bar (1.5 psi... 150 psi)
Main components: Alloy C, 316L, optional: AuPt coating
Process Connection: Thread: G1 1/2, MNPT1 1/2, Flange: DN40... DN100, ASME 2 "... 4", JIS 10K
Maximum measuring distance: 100m (328ft) H_2O
Output: 4... 20 mA HART, PROFIBUS PA, Foundation Fieldbus (FF)
Certificate/Authentication: ATEX, CSA, FM, IECEx, TIIS, NACE, SIL, Detection Certificate, WHG/Overflow Protection
Options: Separated housing, initial instrumentation settings, over-voltage protection
Characteristic: Common module with differential pressure transmitter and process pressure instrument (replaceable display unit, general electronic component), diagnostic function, sealed welding CONTITE measurement unit (anti-condensation and climate corrosion)
Application limitation: When under pressure, differential pressure measurement (electronic differential pressure measurement) is carried out by two pressure transmitters. Pay attention to the pressure ratio: static pressure.
technical parameter
pressure
Measurement Principle: Static Pressure
Characteristic: Pressure transmitter, used for hydrostatic level measurement, metal measuring diaphragm with safety installation: -, sealed welding, - absolutely sealed anti-condensation, - anti-climate change, - long-term stability, - minimum temperature effect, rod type instrument, liquid used in all process areas, process measurement technology, pharmaceutical and food industries Measurement of solid and pasty media,
Power/Communication: 4 20 mA HART: 11.5 45 V DC; Ex ia: 11.5 30 V DC, PROFIBUS PA / Foundation Fieldbus (FF), 9 32 V DC (Non Ex)
Measurement accuracy: 0.2%, optional: 0.1%
Long-term stability: 0.05% of maximum range (URL) per year
Process temperature: - 10 degree C... 85 degrees C (14 degrees F... 212 degrees F)
Ambient temperature: - 40 degree C. 85 degrees C (- 40 degrees F (-) 185 degrees F)
Measuring range: 100 mbar... 10 bar (1.5 psi... 150 psi)
Maximum overvoltage limit: 40 bar (600 psi)
Process Connection: Thread: G1 1/2, MNPT1 1/2, Flange: DN40... DN100, ASME 2 "... 4", JIS 10K
Output: 4... 20 mA HART, PROFIBUS PA, Foundation Fieldbus (FF)
Certificate/Certification: ATEX, CSA, FM, IECEx, TIIS, NACE, SIL, Testing Certificate, Drinking Water Certification, WHG/Spillover Protection
Options: Separated housing, initial instrumentation settings, over-voltage protection
Characteristic: Common module with differential pressure transmitter and process pressure instrument (replaceable display unit, general electronic component), diagnostic function, sealed welding CONTITE measurement unit (anti-condensation and climate corrosion)
Application limitation: When under pressure, differential pressure measurement (electronic differential pressure measurement) is carried out by two pressure transmitters. Pay attention to the pressure ratio: static pressure.