Consultation Hotline:0755-83990550
Ch/En
Localhost:Home > E+H > pressure > static pressure >

Waterpilot_FMX21

technical parameter
Continuum/liquid
Measurement Principle: Static Pressure
Features/Applications: Rod sensor for hydrostatic level measurement, with ceramic measuring unit, diameter 22 mm: conventional application, drinking water, diameter 42 mm: sewage application, diameter 29 mm: brine application, drinking water, HART communication
Power/Communication: 10.5... 35 V DC
Measurement accuracy: 0.2%, optional: 0.1%
Long-term stability: 0.1% of the upper limit of range (URL) per year
Ambient temperature: - 10 degree C.. When the diameter is 29 mm (1.14") and 70 C (14 F 158 F), 0 C. 50 degrees C (32 degrees F... 122 degrees F)
Process temperature: - 10 degree C... When the diameter is 29 mm (1.14") and 70 C (14 F 158 F), 0 C. 50 degrees C (32 degrees F... 122 degrees F), process pressure (absolute pressure)/
Maximum overvoltage limit: 40 bar (600 psi)
Pressure measurement range: 100 mbar... 20 bar (1.5 psi... 300 psi)
Major liquid-connecting parts: when the diameter is 22 mm and 42 mm: sealing ring, 316L, ceramics, when the diameter is 29 mm: PPS, polyolefin, ceramics, extension cable: PE, PUR, FEP
Process Connection: Suspension Installation Clamp, Cable Installation Screw
Maximum measuring distance: 200m (656ft) H_2O
Output: 4... 20 mA HART
Certificate/Certification: ATEX, FM, CSA, IECEx, NSF/KTW/ACS, GL/ABS Classification Certification
Options: absolute voltage measurement unit, built-in Pt100 temperature sensor, four-wire system, user-defined adjustment, user-defined cable marking
Characteristic: Automatic Density Compensation, Non-Metal Process Contact Component Type
Application Limitations: Measurement Unit: Ceramics

technical parameter
pressure
Measurement Principle: Static Pressure
Features/Applications: Rod sensor for hydrostatic level measurement, with ceramic measuring unit, diameter 22 mm: conventional application, drinking water, diameter 42 mm: sewage application, diameter 29 mm: brine application, drinking water, HART communication
Power/Communication: 10.5... 35 V DC
Measurement accuracy: 0.2%, optional: 0.1%
Long-term stability: 0.1% of the upper limit of range (URL) per year
Process temperature: - 10 degree C... When the diameter is 29 mm (1.14") and 70 C (14 F 158 F), 0 C. 50 degrees C (32 degrees F... 122 degrees F)
Ambient temperature: - 10 degree C.. When the diameter is 29 mm (1.14") and 70 C (14 F 158 F), 0 C. 50 degrees C (32 degrees F... 122 degrees F)
Measuring range: 100 mbar... 20 bar (1.5 psi... 300 psi)
When the maximum overvoltage limit is 40 bar (580 psi) and the diameter is 29 mm, it is 25 bar (362 psi).
Process Connection: Suspension Installation Clamp, Cable Installation Screw
Output: 4... 20 mA HART
Certificate/Certification: ATEX, FM, CSA, IECEx, NSF/KTW/ACS, GL/ABS Classification Certification
Options: absolute voltage measurement unit, built-in Pt100 temperature sensor, four-wire system, user-defined adjustment, user-defined cable marking